334 Fieldbus control with embedded fieldbus
11
RAMP_OUT_0
1
Force ramp output to zero.
0
No operation
12
RAMP_HOLD
1
Halt ramping (Ramp function generator output held).
0
No operation
13
RAMP_IN_0
1
Force ramp input to zero.
0
No operation
14
REQ_LOCALLO
C
1
Enable local lock. Entering the local control mode is
disabled (LOC/REM key of the panel).
0
No operation
15
TORQLIM2
1
Use minimum/maximum torque limit 2 (defined by
parameters
).
0
Use minimum/maximum torque limit 1 (defined by
parameters
).
DCU profile Control word, parameter
Bit
Name
Value
Information
16
FBLOCAL_CTL
1
Fieldbus local mode for Control word requested.
Example:
If the drive is in remote control and the
start/stop/direction command source is DI for external
control location 1 (EXT1): by setting bit 16 to value 1, the
start/stop/direction is controlled by the fieldbus command
word.
0
No fieldbus local mode
17
FBLOCAL_REF
1
Fieldbus local mode Control word for reference requested.
See the example for bit 16 (
0
No fieldbus local mode
18
START_DISABL
E1
1
No Start enable
0
Enable start. Effective if parameter
setting is
.
19
START_DISABL
E2
1
No Start enable
0
Enable start. Effective if parameter
setting is
.
20
JOGGING 1
1
Activate jogging 1. Effective if parameter
setting is
. See section
on page
0
Jogging 1 disabled
21
JOGGING 2
1
Activate jogging 2. Effective if parameter
setting is
. See section
on page
0
Jogging 2 disabled
22
…
26
Reserved
DCU profile Control word, parameter
0301 FB CMD WORD 1
Bit
Name
Value
Information
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...