352 Fault tracing
2010
MOTOR TEMP
bit 9
(programmable fault
function
…
)
Motor temperature is
too high (or appears to
be too high) due to
excessive load,
insufficient motor
power, inadequate
cooling or incorrect
start-up data.
For more information, see fault
in
Fault messages generated by the
on page
.
Measured motor
temperature has
exceeded alarm limit
.
2011
UNDERLOAD
bit 10
(programmable fault
function
…
)
Motor load is too low
due to, eg, release
mechanism in driven
equipment.
Check for problem in driven
equipment.
Check fault function parameters.
Check motor power against drive
power.
2012
MOTOR STALL
bit 11
(programmable fault
function
…
)
Motor is operating in
stall region due to, eg,
excessive load or
insufficient motor
power.
Check motor load and drive ratings.
Check fault function parameters.
2013
1)
AUTORESET
bit 12
Automatic reset alarm
Check parameter group
settings.
2018
1)
PID SLEEP
bit 1
(programmable fault
Sleep function has
entered sleeping
mode.
See parameter groups
2019
ID RUN
bit 2
Motor Identification run
is on.
This alarm belongs to normal start-up
procedure. Wait until drive indicates
that motor identification is completed.
2021
START ENABLE 1
MISSING
bit 4
No Start enable 1
signal received
Check parameter
settings.
Check digital input connections.
Check fieldbus communication
settings.
2022
START ENABLE 2
MISSING
bit 5
No Start enable 2
signal received
Check parameter
settings.
Check digital input connections.
Check fieldbus communication
settings.
2023
EMERGENCY
STOP
bit 6
Drive has received
emergency stop
command and ramps
to stop according to
ramp time defined by
Check that it is safe to continue
operation.
Return emergency stop push button to
normal position.
CODE ALARM
CAUSE
WHAT TO DO
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...