62
ACS510 User’s Manual
Start-Up
4210
SET
POINT
SEL
0…2, 8…17, 19, 20
1
1
9
4211
INTERNAL
SETPNT
Unit and scale defined by par. 4206 and
4207
0.0%
40.0%
4212
SETPOINT
MIN
-500.0%…500.0%
0.1%
0.0%
4213
SETPOINT
MAX
-500.0%…500.0%
0.1%
100.0%
4214
FBK
SEL
1…13
1
1
4215
FBK
MULTIPLIER
-32.768…32.767 (0 =
NOT USED
)
0.001
0.000
4216
ACT
1
INPUT
1…7
1
2
9
4217
ACT
2
INPUT
1…7
1
2
9
4218
ACT
1
MINIMUM
-1000…1000%
1%
0%
4219
ACT
1
MAXIMUM
-1000…1000%
1%
100%
4220
ACT
2
MINIMUM
-1000…1000%
1%
0%
4221
ACT
2
MAXIMUM
-1000…1000%
1%
100%
4228
ACTIVATE
-6…8
1
0
4229
OFFSET
0.0…100.0%
0.1%
0.0%
4230
TRIM
MODE
0…3
1
0
4231
TRIM
SCALE
-100.0%…100.0%
0.1%
0.0%
4232
CORRECTION
SRC
1…2
1
1 (
PID
2
REF
)
Group 51: Ext Comm Module
5101
FBA
TYPE
-
-
0
5102 …
5126
FB
PAR
2…26
0...65535
1
0
5127
FBA
PAR
REFRESH
0 = done, 1 = refresh
1
0
9
5128
FILE
CPI
FW
REV
0...0xFFFF (hex)
1
0
5129
FILE
CONFIG
ID
0...0xFFFF (hex)
1
0
5130
FILE
CONFIG
REV
0...0xFFFF (hex)
1
0
5131
FBA
STATUS
0…6
1
0
5132
FBA
CPI
FW
REV
0...0xFFFF (hex)
1
0
5133
FBA
APPL
FW
REV
0...0xFFFF (hex)
1
0
Group 53: EFB Protocol
5301
EFB
PROTOCOL
ID
0...0xFFFF
1
0
5302
EFB
STATION
ID
0…65535
1
1
9
5303
EFB
BAUD
RATE
1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 76.8
kbits/s
-
9.6 kbits/s
5304
EFB
PARITY
0 = 8
NONE
1, 1 = 8
NONE
2, 2 = 8
EVEN
1,
3 = 8
ODD
1
0
5305
EFB
CTRL
PROFILE
0 =
ABB
DRV
LIM
, 1 =
DCU
PROFILE
,
2 =
ABB
DRV
FULL
1
0 (
ABB
DRV
LIM
)
5306
EFB
OK
MESSAGES
0…65535
1
0
5307
EFB
CRC
ERRORS
0…65535
1
0
5308
EFB
UART
ERRORS
0…65535
1
0
5309
EFB
STATUS
0…7
1
0 (
IDLE
)
5310
EFB
PAR
10
0…65535
1
0 (
NOT SEL
)
5311
EFB
PAR
11
0…65535
1
0 (
NOT SEL
)
5312
EFB
PAR
12
0…65535
1
0 (
NOT SEL
)
5313
EFB
PAR
13
0…65535
1
0 (
NOT SEL
)
Code
Name
Range
Resolution
Default
User S
Supplied from China by: Guangzhou Tofee Electro Mechanical Equipment Co., Ltd
Email: info@tofee.com.cn