ACS550-02/U2 User’s Manual
249
Embedded fieldbus
REF1
COMM
*
AI
1
COMM
(%) · (
AI
(%) / 0.5 ·
REF
1
MAX
(%))
REF2
COMM
+
AI
1
COMM
(%) + (
AI
(%) - 0.5 ·
REF
2
MAX
(%))
REF2
COMM
*
AI
1
COMM
(%) · (
AI
(%) / 0.5 ·
REF
2
MAX
(%))
ABB Drives and DCU profiles
Reference
Value
setting
AI reference scaling
0%
50%
200%
(100 - 0.5 · (par. 1105))%
100%
100%
AI1 input signal
Fieldbus reference
correction coefficient
0%
50%
(100 + 0.5 · (Par. 1108)%
(100 - 0.5 · (par. 1108)%
100%
100%
AI1 input signal
Fieldbus reference
correction coefficient
0%
50%
200%
0%
100%
100%
AI1input signal
Fieldbus reference
correction coefficient