Maintenance
Maintenance Intervals
If installed in an appropriate environment, the drive requires very little maintenance. This
table lists the routine maintenance intervals recommended by ABB.
Maintenance
Configuration
Interval
Instruction
Check and clean
heatsink.
All
Depends on the
dustiness of the
environment
(every 6…12
months)
See “Maintenance” in ACS580-01
User’s Manual.
Replace drive
module fan.
All
Every six years
See “Maintenance” in ACS580-01
User’s Manual.
Replace enclosure
fan(s).
NEMA 3R
enclosures
Every three years See “Enclosure Fan Replacement
– UL Type / NEMA 3R. See
“Maintenance” in ACS580-01
User’s Manual.
Change capacitor.
Frame sizes R5 and
R6
Every ten years
See “Maintenance” in ACS580-01
User’s Manual.
Replace battery in
the Assistant
control panel.
All
Every ten years
See “Maintenance” in ACS580-01
User’s Manual.
Drive Module Fan Replacement
The drive module fan cools the heatsink. Fan failure can be predicted by the increasing
noise from fan bearings and the gradual rise in the heatsink temperature in spite of
heatsink cleaning. If the drive is operated in a critical part of a process, fan replacement is
recommended once these symptoms start appearing. Replacement fans are available
from ABB. Do not use other than ABB specified spare parts.
To monitor the running time of the cooling fan, see “Group 29: Maintenance Trig” in the
ACS580-01 Users’s Manual.