Technical data
164
Auxiliary circuit current consumption
The table below shows the current consumption of the main components in the
auxiliary circuit. See also section
Connecting external power supply for the auxiliary
on page
for instructions.
1) values for each single unit
2) total value for multiple units
3) air-cooled IP54 sine filter
Drive/Load
Current consumption (A)
Externally supplied fan circuits
Externally supplied
control circuits
Externally supplied fan and
control circuits
230 V AC 230 V AC 115 V AC
230 V AC 115 V AC
230 V AC 230 V AC 115 V AC
50 Hz
60 Hz
60 Hz
50/60 Hz
60 Hz
50 Hz
60 Hz
60 Hz
Drives
1×R7i + 1×R7i
1×R8i + 1×R8i
n.a.
n.a.
n.a.
1.1
2.2
n.a.
n.a.
n.a.
2×R8i + 2×R8i
5.1
5.8
11.6
2.2
4.4
7.3
8
16
2×R8i + 2×R8i
5.1
5.8
11.6
2.2
4.4
7.3
8
16
3×R8i + 3×R8i
7.3
8.3
17
2.2
4.4
9.5
10.5
21.4
4×R8i + 4×R8i
9.5
11
22
2.2
4.4
11.7
13.2
26.4
6×R8i + 6×R8i
14.5
16.5
32.5
2.5
5
17
19
37.5
8×R8i + 7×R8i
18
21
41
2.5
5
20.5
23.5
46
9×R8i + 8×R8i
21
23
46
2.5
5
23.5
25.5
51
10×R8i + 9×R8i
23
26
52
2.5
5
25.5
28.5
57
Brake units
3-phase brake
units (ACS800-
607LC)
1.4
1.5
3
1)
-
-
-
-
-
NBRW fan unit
0.3
0.3
0.5
1)
-
-
-
-
-
Brake resistors
(2 × SAFUR)
2.8
3.4
6.8
1)
-
-
-
-
-
Control circuit
Single 3-phase
brake unit
-
-
-
0.1
0.2
-
-
-
Multiple 3-phase
brake units
-
-
-
0.5
1
2)
-
-
-
Sine filters
NSIN0210-0485/6
0.35
0.4
0.8
1)
-
-
-
-
-
NSIN0210-0485/6
0.7
0.8
1.6
1) 3)
-
-
-
-
-
NSIN0900-1380/6
2.8
3.4
6.8
1)
-
-
-
-
-
NSIN0900-1380/6
4.8
5.5
11
1) 3)
-
-
-
-
-
Optional cabinets
Top exit
(+H351+H359))
0.35
0.4
0.8
-
-
-
-
-
Cooling unit
(+C139, +C140,
+C141): 24 V DC
power supply and
control relays
See
ACS800-1007LC User’s Manual
(3AFE68621101 [English]).
Summary of Contents for ACS800-17LC
Page 1: ...ABB industrial drives Hardware manual ACS800 17LC Drives 55 to 5200 kW ...
Page 4: ......
Page 10: ...Update notice 6 ...
Page 18: ...Table of contents 12 ...
Page 26: ...Safety instructions 20 ...
Page 32: ...Introduction to the manual 26 ...
Page 60: ...Hardware description 54 ...
Page 74: ...Mechanical installation 68 ...
Page 114: ...Electrical installation 108 ...
Page 142: ...Maintenance 136 ...
Page 150: ...Internal cooling circuit 144 ...
Page 179: ...Dimensions 173 Frame sizes R7i R7i and R8i R8i bottom entry exit ...
Page 180: ...Dimensions 174 Frame sizes R7i R7i and R8i R8i marine units C121 ...
Page 182: ...www abb com drives www abb com drivespartners Contact us 3AUA0000065339 Rev B EN 2016 06 07 ...