404 Fieldbus control through the embedded fieldbus interface (EFB)
Discrete inputs (1xxxx reference set)
Discrete inputs are 1-bit read-only values. Status Word bits are exposed with this data
type. The table below summarizes the Modbus discrete inputs (1xxxx reference set).
00035
Reserved
, bit 2
00036
Reserved
, bit 3
00037
Reserved
, bit 4
00038
Reserved
, bit 5
00039
Reserved
, bit 6
00040
Reserved
, bit 7
00041
Reserved
, bit 8
00042
Reserved
, bit 9
Reference ABB drives profile
Transparent profile
10001
RDY_ON
Status Word bit 0
10002
RDY_RUN
Status Word bit 1
10003
RDY_REF
Status Word bit 2
10004
TRIPPED
Status Word bit 3
10005
OFF_2_STA
Status Word bit 4
10006
OFF_3_STA
Status Word bit 5
10007
SWC_ON_INHIB
Status Word bit 6
10008
ALARM
Status Word bit 7
10009
AT_SETPOINT
Status Word bit 8
10010
REMOTE
Status Word bit 9
10011
ABOVE_LIMIT
Status Word bit 10
10012
User-defined (0)
Status Word bit 11
10013
User-defined (1)
Status Word bit 12
10014
User-defined (2)
Status Word bit 13
10015
User-defined (3)
Status Word bit 14
10016
Reserved
Status Word bit 15
10017
Reserved
Status Word bit 16
10018
Reserved
Status Word bit 17
10019
Reserved
Status Word bit 18
10020
Reserved
Status Word bit 19
10021
Reserved
Status Word bit 20
10022
Reserved
Status Word bit 21
10023
Reserved
Status Word bit 22
10024
Reserved
Status Word bit 23
Reference ABB drives profile
Transparent profile
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...