Parameters 97
Amount of energy that has passed through the drive (towards
the supply) in full gigawatt-hours. The minimum value is zero.
-
0…32767 GWh
Regenerative energy in GWh.
1 = 1 GWh
Amount of energy that has passed through the drive (towards
the supply) in full megawatt-hours. Whenever the counter rolls
over,
is incremented.The
minimum value is zero.
-
0…999 MWh
Regenerative energy in MWh.
1 = 1 MWh
Amount of energy that has passed through the drive (towards
the supply) in full kilowatt-hours. Whenever the counter rolls
over,
minimum value is zero.
-
0…999 kWh
Regenerative energy in kWh.
10 = 1 kWh
Amount of net energy (motoring energy - regenerating
energy) that has passed through the drive in full gigawatt-
hours.
-
-32768…32767
GWh
Energy balance in GWh.
1 = 1 GWh
Amount of net energy (motoring energy - regenerating
energy) that has passed through the drive in full megawatt-
hours. Whenever the counter rolls over,
is incremented or decremented.
-
-999…999 MWh
Energy balance in MWh.
1 = 1 MWh
Amount of energy (motoring energy - regenerating energy)
that has passed through the drive in full kilowatt-hours.
Whenever the counter rolls over,
is incremented or decremented.
-
-999…999 kWh
Energy balance in kWh.
10 = 1 kWh
Absolute value of
.
-
0.00 … 6000.00
rpm
Measured or estimated motor speed.
See par.
Absolute value of
.
-
0.00 … 1000.00%
Measured or estimated motor speed.
10 = 1%
Absolute value of
.
-
0.00 … 100.00 Hz
Estimated output frequency.
See par.
Absolute value of
-
0.0 … 1600.0%
Motor torque.
See par.
Absolute value of
-
0.00 … 32767.00
kW
Output power.
1 = 1 unit
Absolute value of
.
-
0.00 … 300.00%
Output power.
10 = 1%
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...