Parameters 151
Defines a reference to be added to the speed reference after
reference selection (see page
For the selections, see parameter
.
Note:
For safety reasons, the additive is not applied when any
of the stop functions are active.
Defines a scaling factor for the selected speed reference
(speed reference 1 or 2, multiplied by the defined value).
Speed reference 1 or 2 is selected by parameter
1.000
-8.000 …8.000
Speed reference scaling factor.
1000 = 1
Defines a reference to be added to the speed reference after
the speed share function (see page
For the selections, see parameter
.
Note:
For safety reasons, the additive is not applied when any
of the stop functions are active.
Determines how constant speeds are selected, and whether
the rotation direction signal is considered or not when
applying a constant speed.
0000b
0000b…0011b
Constant speed configuration word.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Bit
Name
Information
0
Constant speed
mode
1 = Packed: 7 constant speeds are selectable using the three sources
defined by parameters
,
.
0 = Separate: Constant speeds 1, 2 and 3 are separately activated by
the sources defined by parameters
In case of conflict, the constant speed with the smaller number takes
priority.
1
Direction
enable
1 = Start dir: To determine running direction for a constant speed, the
sign of the constant speed setting (parameters
) is
multiplied by the direction signal (forward: +1, reverse: -1). This
effectively allows the drive to have 14 (7 forward, 7 reverse) constant
speeds if all values in
are positive.
WARNING:
If the direction signal is reverse and the active
constant speed is negative, the drive will run in the forward
direction.
0 = Accord Par: The running direction for the constant speed is
determined by the sign of the constant speed setting (parameters
…
2…15
Reserved
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...