256 Parameters
-
…
…
…
…
See parameter
.
54
Configuration of the embedded fieldbus (EFB) interface.
See also chapter
Fieldbus control through the embedded
).
Enables/disables the embedded fieldbus interface and selects
the protocol to use.
Notes:
• When the embedded fieldbus interface is enabled, the
drive-to-drive link functionality is automatically disabled.
• This parameter cannot be changed while the drive is
running.
None
None (communication disabled).
0
Modbus RTU
Embedded fieldbus interface is enabled and uses the Modbus
RTU protocol.
1
Displays the protocol ID and revision.
This parameter is read-only.
-
Protocol ID and revision.
1 = 1
Defines the node address of the drive on the fieldbus link.
Values 1…247 are allowable. Two devices with the same
address are not allowed on-line.
Changes to this parameter take effect after the control unit is
rebooted or the new settings validated by parameter
1
0…255
Node address (values 1…247 are allowable).
1 = 1
Selects the transfer rate of the fieldbus link.
Changes to this parameter take effect after the control unit is
rebooted or the new settings validated by parameter
9.6 kbps
9.6 kbit/s.
2
19.2 kbps
19.2 kbit/s.
3
38.4 kbps
38.4 kbit/s.
4
57.6 kbps
57.6 kbit/s.
5
76.8 kbps
76.8 kbit/s.
6
115.2 kbps
115.2 kbit/s.
7
Selects the type of parity bit and the number of stop bits.
Changes to this parameter take effect after the control unit is
rebooted or the new settings validated by parameter
8 NONE 1
Eight data bits, no parity bit, one stop bit.
0
8 NONE 2
Eight data bits, no parity bit, two stop bits.
1
8 EVEN 1
Eight data bits, even parity bit, one stop bit.
2
8 ODD 1
Eight data bits, odd parity bit, one stop bit.
3
Validates any changes in the EFB settings, or activates silent
mode.
Enabled
Normal operation.
0
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...