30 Operation principle and hardware description
Type designation keys
Type designation key of the converter unit
Type designation describes the composition of the unit in short. The type designation is
visible on the label (sticker) which is attached to the cabinet. The complete designation
code is divided in subcodes:
•
The first 1…18 digits form the basic code. It describes the basic construction of the
unit. The fields in the basic code are separated by hyphens.
•
The option codes follow the basic code. Each option code starts with an identifying
letter (common for the whole product series), followed by descriptive digits. The option
codes are separated by plus signs.
This is a list of options codes. The standard features are marked with *.
CODE
DESCRIPTION
Basic codes
ACS880 Product
series
1607
Construction: cabinet-installed DC/DC converter unit. When no options are selected: Supply
frequency 50 Hz, control voltage 230 V AC, IP22 (UL type 1), EN/IEC industrial cabinet
construction, power and control cabling through the bottom of the cabinet, DC busbar material
aluminum, cable supply conductors, standard wiring material, speed-controlled fan, ACS880
DC/DC converter control program, complete documentation in English in memory stick.
Size
0900A
Refer to
the rating tables on page
Voltage range
3
DC voltage corresponding AC input voltages 3
380…415 V. This is indicated in the type
designation label as typical input voltage level 566 V DC.
5
DC voltage corresponding AC input voltages 3
380…500 V. This is indicated in the type
designation label as typical input voltage levels 566 / 679 / 707 V DC.
7
DC voltage corresponding AC input voltages 3
525…690 V. This is indicated in the type
designation label as typical input voltage levels 742 / 849 / 976 (849 UL/CSA) V DC.
Code
Description
+A012
Supply frequency
Supply frequency 50 Hz
*
+A013
Supply frequency
Supply frequency 60 Hz
+B053
Degree of protection
IP22, UL type 1
*
+B054
Degree of protection
IP42, UL type 1
+B055
Degree of protection
IP54, UL type 12
+C121
Cabinet construction
Marine construction
+C128
Channeled air
Cooling air through bottom
+C129
Standards
UL-approved
+C130
Channeled air outlet
Channeled air outlet
+C132
Marine type approval
Marine type-approved DC/DC converter unit
+C134
Standards
CSA-approved
+C164
Cabinet options
Plinth height 1 (100 mm)
+C180
Cabinet construction
Seismic design
+C188
DOL cooling fan
DOL cooling fan
+E210
EMC
2nd environment
+F286
DC switch/disconnector
DC switch/disconnector
+G300
Cabinet options
Cabinet heater
+G301
Cabinet options
Cabinet lighting
+G304
Auxiliary voltage distribution
115 V AC
~
~
~
Summary of Contents for ACS880-1607
Page 1: ...ABB industrial drives Hardware manual ACS880 1607 DC DC converter units ...
Page 4: ......
Page 12: ...12 Introduction to the manual ...
Page 34: ...34 Mechanical installation ...
Page 40: ...40 Guidelines for planning electrical installation ...
Page 52: ...52 Electrical installation ...
Page 68: ...68 Start up ...
Page 80: ...80 Maintenance 7 3 4 5 6 ...
Page 82: ...82 Maintenance 3 4 5 6 7 8 9 9 ...
Page 85: ...Maintenance 85 12 Install and tighten the two screws 10 11 12 ...
Page 92: ...92 Maintenance 3 6 4 5 4 7a 7b 7b ...
Page 93: ...Maintenance 93 9 8 8 10 11 ...
Page 96: ...96 Maintenance 4 8 6 7 5 3 ...
Page 97: ...Maintenance 97 9 ...
Page 118: ...118 Dimensions Dimension drawings Frame 1 R8i bottom cable entry ...
Page 119: ...Dimensions 119 Frame 1 R8i top cable entry ...
Page 122: ...www abb com drives www abb com drivespartners 3AXD50000023644 Rev B EN 2017 01 30 Contact us ...