Technical data 179
Sine output filter data
Sine output filters are available as E206. The table below shows the types and
technical data of the filters and filter cubicles used in ACS880-37 drives.
Terminal and lead-through data for the power cables
The locations and sizes of lead-throughs are shown by the dimension drawings delivered
with the drive, and the dimension drawing examples starting on page
.
The location and size of power cable terminals are shown in the drawings starting on page
.
Terminal data for the supply and inverter control units
See chapter
(page
Drive type
ACS880-37-…
Sine filter(s) used
Nominal
current
Cooling data
Dimensions
Qty
Type
Heat
dissipation
Air flow
Width
Weight
A
kW
m
3
/h (ft
3
/min)
mm
kg (lbs)
U
N
= 400 V
0450A-3
1
NSIN-0485-6
447
2
700 (410)
400
350 (770)
0620A-3
1
NSIN-0900-6
783
5
2000 (1180)
1000
550 (1210)
0870A-3
1
NSIN-1380-6
1201
7
2000 (1180)
1000
750 (1650)
1110A-3
1
NSIN-1380-6
1201
7
2000 (1180)
1000
750 (1650)
1210A-3
1
NSIN-1380-6
1201
7
2000 (1180)
1000
750 (1650)
1430A-3
2
NSIN-0900-6
1488
10
4000 (2350)
2000
1100 (2430)
1700A-3
2
NSIN-1380-6
2282
14
4000 (2350)
2000
1500 (3310)
2060A-3
2
NSIN-1380-6
2282
14
4000 (2350)
2000
1500 (3310)
2530A-3
3
NSIN-1380-6
3387
21
6000 (3530)
3000
2250 (4960)
U
N
= 500 V
0420A-5
1
NSIN-0485-6
447
2.5
700 (410)
400
350 (770)
0570A-5
1
NSIN-0900-6
783
6
2000 (1180)
1000
550 (1210)
0780A-5
1
NSIN-0900-6
783
6
2000 (1180)
1000
550 (1210)
1010A-5
1
NSIN-1380-6
1201
8
2000 (1180)
1000
750 (1650)
1110A-5
1
NSIN-1380-6
1201
8
2000 (1180)
1000
750 (1650)
1530A-5
2
NSIN-1380-6
2282
16
4000 (2350)
2000
1500 (3310)
1980A-5
2
NSIN-1380-6
2282
16
4000 (2350)
2000
1500 (3310)
2270A-5
2
NSIN-1380-6
2282
16
4000 (2350)
2000
1500 (3310)
U
N
= 690 V
0320A-7
1
NSIN-0485-6
447
3
700 (410)
400
350 (770)
0390A-7
1
NSIN-0485-6
447
3
700 (410)
400
350 (770)
0580A-7
1
NSIN-0900-6
783
7
2000 (1180)
1000
550 (1210)
0660A-7
1
NSIN-0900-6
783
7
2000 (1180)
1000
550 (1210)
0770A-7
1
NSIN-0900-6
783
7
2000 (1180)
1000
550 (1210)
0950A-7
1
NSIN-1380-6
1201
9
2000 (1180)
1000
750 (1650)
1130A-7
1
NSIN-1380-6
1201
9
2000 (1180)
1000
750 (1650)
1450A-7
2
NSIN-0900-6
1488
14
4000 (2350)
2000
1100 (2430)
1680A-7
2
NSIN-1380-6
2282
18
4000 (2350)
2000
1500 (3310)
1950A-7
2
NSIN-1380-6
2282
18
4000 (2350)
2000
1500 (3310)
2230A-7
2
NSIN-1380-6
2282
18
4000 (2350)
2000
1500 (3310)
2770A-7
3
NSIN-1380-6
3387
27
6000 (3530)
3000
2250 (4960)
3310A-7
3
NSIN-1380-6
3387
27
6000 (3530)
3000
2250 (4960)
Summary of Contents for ACS880-17
Page 1: ...ABB industrial drives Hardware manual ACS880 37 drives ...
Page 3: ......
Page 4: ......
Page 6: ......
Page 16: ...16 ...
Page 30: ...30 Introduction to the manual ...
Page 70: ...70 Mechanical installation ...
Page 105: ...Electrical installation 105 4 5 3 6 7 ...
Page 107: ...Electrical installation 107 5 6 4 3 ...
Page 108: ...108 Electrical installation 7 8 8 ...
Page 109: ...Electrical installation 109 9 10 ...
Page 111: ...Electrical installation 111 2 360 grounding detail a b b 1 5 a 11 b a PE 10 7 5 6 8 ...
Page 117: ...Electrical installation 117 PE 11 8 4 9 11 ...
Page 134: ...134 Control units of the drive ...
Page 140: ...140 Start up ...
Page 142: ...142 Fault tracing ...
Page 154: ...154 Maintenance 4 5 6 7 8 6 10 10 ...
Page 162: ...162 Maintenance 5 6 3 4 7 ...
Page 163: ...Maintenance 163 6 8 7 11 10 9 ...
Page 167: ...Maintenance 167 3 4b 4a 4b 8 ...
Page 185: ...Technical data 185 Declaration of Conformity ...
Page 186: ...186 Technical data ...
Page 196: ...196 Dimensions Dimension drawing examples Frame 1 R8i 1 R8i ...
Page 197: ...Dimensions 197 Frame 1 R8i 1 R8i top cable entry exit H351 H353 ...
Page 198: ...198 Dimensions Frame 1 R8i 1 R8i with brake choppers and resistors D150 D151 ...
Page 199: ...Dimensions 199 Frame 1 R8i 1 R8i with sine output filter E206 ...
Page 200: ...200 Dimensions Frame 2 R8i 2 R8i eg ACS880 37 1110A 3 IP22 ...
Page 201: ...Dimensions 201 Frame 2 R8i 2 R8i eg ACS880 37 1210A 3 IP54 ...
Page 204: ...204 Dimensions Frame 2 R8i 2 R8i with main breaker F255 and top entry top exit H351 H353 1 2 ...
Page 205: ...Dimensions 205 Frame 2 R8i 2 R8i with main breaker F255 and top entry top exit H351 H353 2 2 ...
Page 206: ...206 Dimensions Frame 3 R8i 3 R8i 1 2 ...
Page 207: ...Dimensions 207 Frame 3 R8i 3 R8i 2 2 ...
Page 208: ...208 Dimensions Frame 3 R8i 3 R8i with common motor terminal cubicle H359 1 2 ...
Page 209: ...Dimensions 209 Frame 3 R8i 3 R8i with common motor terminal cubicle H359 2 2 ...
Page 217: ...Dimensions 217 Sine filter E206 cubicle 1000 mm top cable exit ...
Page 221: ...Dimensions 221 Cubicle width 400 mm top cable exit Cubicle width 600 mm bottom cable exit ...
Page 222: ...222 Dimensions Cubicle width 600 mm top cable exit ...
Page 234: ...234 The Safe torque off function ...
Page 244: ...www abb com drives www abb com drivespartners 3AXD50000020437 Rev A EN 2015 02 06 Contact us ...