Description
Code
FSE-31 pulse encoder interface module
L521
FAIO-01 analog I/O extension module
L525
FDIO-01 digital I/O extension module
L526
FPTC-01 thermistor protection module
L536
FPTC-02 ATEX-certified thermistor protection module
L537
Starter for auxiliary motor fan
(see section
Descriptions of options (page 50)
Trip limit setting range: 1 … 1.6 A
M600
Trip limit setting range: 1.6 … 2.5 A
M601
Trip limit setting range: 2.5 … 4 A
M602
Trip limit setting range: 4 … 6.3 A
M603
Trip limit setting range: 6.3 … 10 A
M604
Trip limit setting range: 10…16 A
M605
Control program
Winder control program
N5000
Crane control program
N5050
Winch control program
N5100
Decanter/Centrifuge control program
N5150
PCP (Progressive Cavity Pump) control program
N5200
Test bench control program
N5300
Override control program
N5450
ESP (Electrical Submersible Pump) control program
N5600
Position control program
N5700
Control program for synchronous reluctance motors (SynRM)
N7502
IEC 61131-3 application programmability
N8010
Specialties
Customized
P902
Extended warranty (30 months from delivery or 24 months from commissioning)
P904
Extended warranty (42 months from delivery or 36 months from commissioning)
P909
Extended warranty (66 months from delivery or 60 months from commissioning)
P911
Seaworthy packaging
P912
Special RAL Classic color
P913
Container packaging
P929
Customized extended warranty
P948
Country of origin: Finland
P952
Special color (other than RAL Classic)
P966
Safety functions
Prevention of unexpected start-up with FSO-xx safety functions module, by activating the Safe
torque off function
Q950
Emergency stop (category 0) with safety relays, by opening the main breaker/contactor
Q951
Emergency stop (category 1) with safety relays, by opening the main breaker/contactor
Q952
Earth fault monitoring for IT (ungrounded) systems
Q954
Prevention of unexpected start-up with safety relays, by activating the Safe torque off function
Q957
Operation principle and hardware description 61
Summary of Contents for ACS880-37
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 37 drives 45 400 kW 60 450 hp Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 83: ...Mechanical installation 83 10 ...
Page 84: ...84 ...
Page 126: ... B055 a X504 126 Electrical installation ...
Page 144: ...144 ...
Page 150: ...150 ...
Page 152: ...152 ...
Page 160: ... 160 Maintenance ...
Page 196: ... 196 Maintenance ...
Page 232: ...R8 IP22 UL Type 1 and option B054 IP42 UL Type 1 Filtered 232 Dimension drawings ...
Page 233: ...R8 IP54 UL Type 12 option B055 option C129 Dimension drawings 233 ...
Page 235: ...R8 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option E206 Dimension drawings 235 ...
Page 236: ...R8 IP22 UL Type 1 option E202 236 Dimension drawings ...
Page 237: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 Dimension drawings 237 ...
Page 238: ...R11 IP54 UL Type 12 option B055 238 Dimension drawings ...
Page 240: ...R11 IP54 UL Type 12 option B055 option C128 240 Dimension drawings ...
Page 241: ...R11 IP54 UL Type 12 option B055 option C129 Dimension drawings 241 ...
Page 242: ...R11 IP54 UL Type 12 option B055 options C129 H350 H352 242 Dimension drawings ...
Page 243: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option D150 Dimension drawings 243 ...
Page 245: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option E206 Dimension drawings 245 ...
Page 246: ...R11 IP22 UL Type 1 option E202 246 Dimension drawings ...
Page 267: ... Declaration of conformity The Safe torque off function 267 ...
Page 268: ...268 The Safe torque off function ...
Page 280: ...280 ...