Description
Code
Emergency stop (category 0) with safety relays, by activating the Safe torque off function
Q963
Emergency stop (category 1) with safety relays, by activating the Safe torque off function
Q964
Safely-limited speed with FSO-21 and encoder
Q965
ATEX-certified safe disconnection function
Q971
FSO-21 safety functions module
Q972
FSO-12 safety functions module
Q973
Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by opening
the main breaker/contactor
Q978
Emergency stop (configurable for category 0 or 1) with FSO-xx safety functions module, by activating
the Safe torque off function
Q979
PROFIsafe with FSO-xx safety functions module and FENA-21 Ethernet adapter module
Q982
FSPS-21 PROFIsafe safety functions module
Q986
Full set of printed manuals in the selected language
Note:
The delivery may include manuals in English if the requested language is not available.
English
R700
German
R701
Italian
R702
Dutch
R703
Danish
R704
Swedish
R705
Finnish
R706
French
R707
Spanish
R708
Portuguese
R709
Russian
R711
Chinese
R712
Polish
R713
Turkish
R714
62 Operation principle and hardware description
Summary of Contents for ACS880-37
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 37 drives 45 400 kW 60 450 hp Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 83: ...Mechanical installation 83 10 ...
Page 84: ...84 ...
Page 126: ... B055 a X504 126 Electrical installation ...
Page 144: ...144 ...
Page 150: ...150 ...
Page 152: ...152 ...
Page 160: ... 160 Maintenance ...
Page 196: ... 196 Maintenance ...
Page 232: ...R8 IP22 UL Type 1 and option B054 IP42 UL Type 1 Filtered 232 Dimension drawings ...
Page 233: ...R8 IP54 UL Type 12 option B055 option C129 Dimension drawings 233 ...
Page 235: ...R8 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option E206 Dimension drawings 235 ...
Page 236: ...R8 IP22 UL Type 1 option E202 236 Dimension drawings ...
Page 237: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 Dimension drawings 237 ...
Page 238: ...R11 IP54 UL Type 12 option B055 238 Dimension drawings ...
Page 240: ...R11 IP54 UL Type 12 option B055 option C128 240 Dimension drawings ...
Page 241: ...R11 IP54 UL Type 12 option B055 option C129 Dimension drawings 241 ...
Page 242: ...R11 IP54 UL Type 12 option B055 options C129 H350 H352 242 Dimension drawings ...
Page 243: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option D150 Dimension drawings 243 ...
Page 245: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option E206 Dimension drawings 245 ...
Page 246: ...R11 IP22 UL Type 1 option E202 246 Dimension drawings ...
Page 267: ... Declaration of conformity The Safe torque off function 267 ...
Page 268: ...268 The Safe torque off function ...
Page 280: ...280 ...