Output ratings
App.
power
Max cur-
rent
Input cur-
rent
Frame
size
Drive type
ACS880-37-…
Heavy-duty use
Light-overload use
P
Hd
I
Hd
P
Ld
I
Ld
S
N
I
max
I
1
hp
A
hp
A
kVA
A
A
250
302
300
361
313
542
257
R11
0361A-5
300
361
350
414
359
542
321
R11
0414A-5
350
414
350
430
398
560
404
R11
0460A-5
400
483
400
483
436
560
455
R11
0503A-5
U
N
= 600 V
150
144
175
168
208
274
149
R11
0174A-7
175
174
200
200
251
384
186
R11
0210A-7
200
210
250
257
324
411
232
R11
0271A-7
250
271
300
320
394
480
293
R11
0330A-7
300
330
350
360
442
520
330
R11
0370A-7
350
370
450
420
514
520
375
R11
0430A-7
3AXD10000425795
■
Definitions
Nominal rms input current at 40 °C (104 °F)
I
1
Continuous rms output current. No overload capability at 40 °C (104 °F)
I
2
Maximum output current. Available for 10 seconds at start, then as long as allowed by drive tempera-
ture.
I
max
Typical motor power in no-overload use
P
N
Apparent power in no-overload use
S
N
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes.
I
Ld
1)
No overload
Typical motor power in light-overload use
P
Ld
Continuous rms output current allowing 50% overload for 1 minute every 5 minutes.
I
Hd
Typical motor power in heavy-duty use
P
Hd
Note:
•
The ratings apply at an ambient temperature of 40 °C (104 °F).
•
To achieve the rated motor power given in the table, the rated current of the drive must
be higher than or equal to the rated motor current.
The DriveSize dimensioning tool available from ABB is recommended for selecting the drive,
motor and gear combination.
■
Derating
Surrounding air temperature derating
In the temperature range +40…50 °C (+104…122 °F), the rated output current is derated
by 1% for every added 1 °C (1.8 °F).
To calculate the output current, multiply the current in the ratings table by the derating factor
(k):
Technical data 205
Summary of Contents for ACS880-37
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 37 drives 45 400 kW 60 450 hp Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 83: ...Mechanical installation 83 10 ...
Page 84: ...84 ...
Page 126: ... B055 a X504 126 Electrical installation ...
Page 144: ...144 ...
Page 150: ...150 ...
Page 152: ...152 ...
Page 160: ... 160 Maintenance ...
Page 196: ... 196 Maintenance ...
Page 232: ...R8 IP22 UL Type 1 and option B054 IP42 UL Type 1 Filtered 232 Dimension drawings ...
Page 233: ...R8 IP54 UL Type 12 option B055 option C129 Dimension drawings 233 ...
Page 235: ...R8 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option E206 Dimension drawings 235 ...
Page 236: ...R8 IP22 UL Type 1 option E202 236 Dimension drawings ...
Page 237: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 Dimension drawings 237 ...
Page 238: ...R11 IP54 UL Type 12 option B055 238 Dimension drawings ...
Page 240: ...R11 IP54 UL Type 12 option B055 option C128 240 Dimension drawings ...
Page 241: ...R11 IP54 UL Type 12 option B055 option C129 Dimension drawings 241 ...
Page 242: ...R11 IP54 UL Type 12 option B055 options C129 H350 H352 242 Dimension drawings ...
Page 243: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option D150 Dimension drawings 243 ...
Page 245: ...R11 IP22 UL Type 1 and IP42 UL Type 1 Filtered option B054 option E206 Dimension drawings 245 ...
Page 246: ...R11 IP22 UL Type 1 option E202 246 Dimension drawings ...
Page 267: ... Declaration of conformity The Safe torque off function 267 ...
Page 268: ...268 The Safe torque off function ...
Page 280: ...280 ...