Parameters 257
Sets the warning limit for signal edge counter 1.
0
0…4294967295
Warning limit for signal edge counter 1.
-
Configures signal edge counter 1.
0000b
0000b…1111b
Edge counter 1 configuration word.
1 = 1
Selects the signal to be monitored by signal edge
counter 1.
False
Constant 0.
0
True
Constant 1.
1
RO1
Bit 0 of
).
2
Source selection (see
on
page
-
Defines a divisor for signal edge counter 1. Determines
how many signal edges increment the counter by 1.
1
1…4294967295
Divisor for signal edge counter 1.
-
Selects the optional warning message for signal edge
counter 1.
Edge counter 1
exceeded
. The message text can be edited on
the control panel by choosing Menu – Settings – Edit texts.
2
Counted main
contactor
.
11
Counted output relay
12
Counted motor starts
13
Counted power ups
14
Counted DC charges
.
15
No.
Name/Value
Description
Def/
FbEq16
Bit
Function
0
Counter mode
0 = Loop: When the limit is reached, the counter is reset. The counter status (bit 2 of
) switches to 1 and remains so until the counter is again incremented. The warning
(if enabled) stays active for at least 10 seconds.
1 = Saturate: When the limit is reached, the counter status (bit 2 of
) switches to 1,
and remains so until
is reset. The warning (if enabled) also stays active until
is reset.
1
Warning enable
0 = Disable: No warning is given when the limit is reached
1 = Enable: A warning (see
) is given when the limit is reached
2
Count rising edges
0 = Disable: Rising edges are not counted
1 = Enable: Rising edges are counted
3
Count falling edges
0 = Disable: Falling edges are not counted
1 = Enable: Falling edges are counted
4…15
Reserved
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...