396 Additional parameter data
75.14
Sleep signal source 1
-
-
1 = 1
75.15
Sleep signal source 2
-
-
1 = 1
75.16
Sleep level
0.00...100000000.00
%
100 = 1%
75.17
Sleep delay time
0.000...10000.000
s
1000 = 1 s
75.18
Wakeup level
0.00...100000000.00
%
100 = 1%
75.19
Wakeup delay time
0.000...10000.000
s
1000 = 1 s
75.20
Maximum sleep time
0.000...100000.000
s
1000 = 1 s
76 Pump pressure protection
76.01
Pressure protection function
-
-
1 = 1
76.02
Pressure protection latching
0...2
-
1 = 1
76.03
Digital feedback source enable
-
-
1 = 1
76.04
Digital feedback source
-
-
1 = 1
76.05
Analog feedback source
enable
-
-
1 = 1
76.06
Analog feedback source
-
-
1 = 1
76.07
Analog feedback limit
0.00...10000.00
kPa or psi
100 = 1 kPa
or psi
76.08
Analog feedback limit delay
time
0.000...3600.000
s
1000 = 1 s
77 Pump torque protection
77.01
Rod torq limit display
-
-
1 = 1
77.02
Rod torq1 function
-
-
1 = 1
77.03
Rod torq1 limit type
-
-
1 = 1
77.04
Rod torq1 limit
0.00...10000.00
N•m, lbft
or A
100 = 1 N•m,
lbft or A
77.05
Rod torq1 speed
-3600.00...3600.00
Prpm, rpm
or Hz
100 = 1 Prpm,
rpm or Hz
77.06
Rod torq1 delay time
0.000...10000.000
s
1000 = 1 s
77.07
Rod torq2 function
-
-
1 = 1
77.08
Rod torq2 limit type
-
-
1 = 1
77.09
Rod torq2 limit
0.00...10000.00
N•m, lbft
or A
100 = 1 N•m,
lbft or A
77.10
Rod torq2 delay time
0.000...10000.000
s
100 = 1 s
77.11
Rod torq2 additive speed ref
-3600.00...3600.00
Prpm, rpm
or Hz
100 = 1 Prpm,
rpm or Hz
77.12
Rod torq2 speed delay time
0.000...100000.000
s
1000 = 1 s
77.13
Rod torq2 limit counter
0...100
-
1 = 1
77.14
Rod torq2 time window
0.000...7200.000
s
1000 = 1 s
No.
Name
Type
Range
Unit
FbEq32
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...