428 Fault tracing
Version mismatch between
EFB protocol firmware and
drive firmware.
6881
Text data overflow
Internal fault.
Reset the fault. Contact your local
ABB representative if the fault
persists.
6882
Text 32-bit table overflow
Internal fault.
Reset the fault. Contact your local
ABB representative if the fault
persists.
6883
Text 64-bit table overflow
Internal fault.
Reset the fault. Contact your local
ABB representative if the fault
persists.
6885
Text file overflow
Internal fault.
Reset the fault. Contact your local
ABB representative if the fault
persists.
7080
Option module comm loss
Communication between
drive and option module
(FEN-xx and/or FIO-xx) is
lost.
Check that the option modules are
properly seated in their slots.
Check that the option modules or
slot connectors are not damaged.
To pinpoint the problem, try
installing the modules into different
slots.
7081
Panel port communication
Programmable fault:
Control panel or PC tool
selected as active control
location for drive has ceased
communicating.
Check PC tool or control panel
connection.
Check control panel connector.
Disconnect and reconnect the
control panel.
Check the auxiliary code.
7082
Extension I/O type
mismatch
The I/O extension module
types specified by
parameters do not match the
detected configuration.
Check the auxiliary code. The code
indicates which I/O extension
module is affected.
Check the type and location
settings of the modules
(parameters
,
Check that the modules are
properly installed.
7121
Motor stall
Programmable fault:
Motor is operating in stall
region because of e.g.
excessive load or insufficient
motor power.
Check motor load and drive
ratings.
Check fault function parameters.
7181
Brake resistor
Brake resistor broken or not
connected.
Check that a brake resistor has
been connected.
Check the condition of the brake
resistor.
Check the dimensioning of the
brake resistor.
Code
(hex)
Fault
Cause
What to do
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...