432 Fault tracing
Aux code: 1015
Load feedback configuration
error (for example, a
nonexistent encoder has
been selected as feedback
source).
Check the settings of parameter
, and the status of the
.
In case the source is an encoder
interface, check parameter settings
in groups
Aux code: 1016
Unexpected load feedback.
Check the settings of parameter
, and the status of the
.
In case the source is an encoder
interface, check parameter settings
in groups
. Check that the
encoder is mounted so that no
slippage is possible.
73B0
Emergency ramp failed
Emergency stop did not
finish within expected time.
Check the settings of parameters
Check the predefined ramp times
(
for mode Off1,
for mode Off3).
73B1
Stop failed
Ramp stop did not finish
within expected time.
Check the settings of parameters
and
.
Check the predefined ramp times in
parameter group
7510
FBA A communication
Programmable fault:
Cyclical communication
between drive and fieldbus
adapter module A or
between PLC and fieldbus
adapter module A is lost.
Check status of fieldbus
communication. See user
documentation of fieldbus
interface.
Check settings of parameter
groups
Check cable connections.
Check if communication master is
able to communicate.
7520
FBA B communication
Programmable fault:
Cyclical communication
between drive and fieldbus
adapter module B or between
PLC and fieldbus adapter
module B is lost.
Check status of fieldbus
communication. See user
documentation of fieldbus interface.
Check settings of parameter group
Check cable connections.
Check if communication master is
able to communicate.
7583
Line side unit faulted
The supply unit (or other
converter) connected to the
inverter unit has generated a
fault.
Check fault status of supply unit (or
other converter).
Refer to the firmware manual of the
supply unit.
Code
(hex)
Fault
Cause
What to do
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...