Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0 MWh / int16
Amount of net energy (motoring energy - regenerating
energy) that has passed through the drive in full
megawatt hours. Whenever the counter rolls over,
Mot - regen energy GWh (resettable)
is incremented or
decremented.
You can reset the value by setting it to zero. Resetting
any of the parameters
to
resets all.
Mot - regen energy
MWh (resettable)
1.36
1 = 1 MWh / 1 = 1 MWh
Energy balance in MWh.
-1000...1000 MWh
0 kWh / real32
Amount of energy (motoring energy - regenerating
energy) that has passed through the drive in full
kilowatt-hours.
Whenever the counter rolls over,
is incremented or decremented.
You can reset the value by setting it to zero. Resetting
any of the parameters
to
resets all.
Mot - regen energy
kWh (resettable)
1.37
10 = 1 kWh / 1 = 1 kWh
Energy balance in kWh.
-1000...1000 kWh
- / real32
Absolute value of
.
Abs motor speed
used
1.61
- / -
Measured or estimated motor speed. For scaling, see
parameter
0.00 ... 30000.00
rpm
- / real32
Absolute value of
Abs motor speed %
1.62
10 = 1 % / 100 = 1 %
Measured or estimated motor speed.
0.00 ... 1000.00 %
- / real32
Absolute value of
Abs output
frequency
1.63
- / -
Estimated output frequency. For scaling, see parameter
0.00 ... 600.00 Hz
- / real32
Absolute value of
Abs motor torque
1.64
- / -
Motor torque. For scaling, see parameter
0.0 ... 1600.0 %
- / real32
Absolute value of
Abs output power
1.65
1 = 1 kW or hp / 100 =
1 kW or hp
Output power.
0.00 ... 32767.00 kW
or hp
- / real32
Absolute value of
1.15 Output power % of motor nom
.
Abs output power %
motor nom
1.66
10 = 1 % / 100 = 1 %
Output power.
0.00 ... 300.00 %
- / real32
Absolute value of
.
Abs motor shaft
power
1.68
1 = 1 kW or hp / 100 =
1 kW or hp
Motor shaft power.
0.00 ... 32767.00 kW
or hp
0.00 % / real32
Measured temperature of incoming cooling air.
The amplitude range of 0…100 % corresponds to
0…60 °C or 32…140 °F.
See also
.
Ambient
temperature %
1.70
1 = 1 % / 100 = 1 %
Cooling air temperature.
-200.00 ... 200.00 %
- / real32
U-phase rms current.
U-phase RMS
current
1.72
Parameters 137
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...