Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
1 = Channel CH12 is routed to a local power unit
b11
Reserved
b12…15
1 = 1
0000h…FFFFh
- / uint16
Specifies hardware-related options that require
differentiated parameter defaults. Activating a bit in
this parameter makes the necessary changes in other
parameters. For example, activating an emergency stop
option reserves a digital input. In many cases, the
differentiated parameters will also be write-protected.
This parameter, as well as the changes in other
parameters implemented by it, are not affected by a
parameter restore.
WARNING! After switching any bits in this word,
recheck the values of the affected parameters.
Note: This parameter cannot be changed while the
drive is running.
*See section
Control of a supply unit (LSU) (page 76)
HW options word 1
95.20
0 = 50 Hz; 1 = 60 Hz. Affects
,
,
,
,
,
,
.
Supply frequency 60
Hz
b0
1 = Emergency stop, Category 0, without FSO module.
Affects
,
Emergency stop Cat
0
b1
1 = Emergency stop, Category 1, without FSO module.
Affects
,
,
.
Emergency stop Cat
1
b2
1 = Control of cabinet cooling fan (used only with
specific ACS880-07 hardware). Affects
RO2 for -07 cabinet
cooling fan
b3
1 = Control unit powered externally. Affects
.
(Only
visible with a ZCU control unit)
Externally powered
control unit
b4
1 = DC switch monitoring active. Affects
,
(Only visible with a ZCU control unit)
DC supply switch
b5
1 = Motor fan control active. Affects
,
,
DOL motor switch
b6
1 = xSFC charging controller used. Affects
.
(Only
visible with a BCU control unit)
xSFC-01 fuse switch
controller
b7
1 = Service switch or PTC/Pt100 relay connected.
Affects
,
.
Service switch or
PTC/Pt100 relay
b8
1 = Output contactor present. Affects
.
Output contactor
b9
1 = Status (eg. thermal) switches connected to DIIL
input. Affects
,
Brake resistor, sine
filter, IP54 fan
b10
*1 = Diode supply unit control by inverter unit active.
Makes several parameters visible in groups
and
(Only visible with a BCU control unit)
INU-DSU
communication
b11
Reserved
b12
Parameters 513
Summary of Contents for ACS880 N5700 Series