What to do
Cause
Event name /
Aux. code
Code
(hex)
Gear-in jump mode requested while
not in synchronization, or D2D speed
is zero.
1013 (3F5h)
Buffer for buffered movement full.
1015 (3F7h)
Command not executable because
the axis is disabled, the command
1101 (44Dh)
was issued during stopping state
(stop command activated), or
minimum distance criteria is not
fulfilled.
Maximum number (63) of immediate
commands reached.
1102 (44Eh)
Buffered command not allowed.
1104 (450h)
Enabled, but deceleration = 0.
1105 (451h)
Check the auxiliary code.
Axis returned a “motion status” error.
Error Stop
State
E204
Limit switch reached.
1011 (3F3h)
Axis disabled.
-
Axis velocity limit reached.
-
Required movement not possible
because it is smaller than the
-
minimum distance allowed by actual
axis velocity/position.
Gearing not possible because of
incorrect profile data.
-
Profile calculation: Axis overshoot
and no adaption.
-
Profile calculation: Travel target is
in opposite direction to initial
speed.
-
Check the auxiliary code.
Problem with configuration of stop
values.
Fast Stop
configuration
E205
<
.
1
= 0, or
2
is not 0 but is not smaller than
.
Check setting of
Actual velocity has exceeded maximum
velocity.
Maximum
velocity
exceeded
E206
Check that the motor ID run was
performed properly according to
instructions.
Check that the drive does not exceed
its limits (parameter group
)
during profile execution.
Check safety circuit connections. For
more information, see appropriate
Safe torque off function is active, ie.
STO circuit 1 is broken.
Safe torque
off 1 loss
FA81
drive hardware manual and
description of parameter
indication run/stop (page 320)
592 Fault tracing
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...