STATE/Description
Value
Name
Bit
Accelerate to jogging 2 reference.
1
JOGGING_2
9
See notes at bit 8.
Jogging 2 disabled.
0
Fieldbus control enabled.
1
REMOTE_ CMD
10
Control word and reference will not get through
to the drive, except for CW bits OFF1, OFF2 and
OFF3.
0
Select External Control Location EXT2. Effective
if the control location is parameterized to be se-
lected from the fieldbus.
1
EXT_CTRL_ LOC
11
Select External Control Location EXT1. Effective
if the control location is parameterized to be se-
lected from the fieldbus.
0
Reserved
12...15
■
Status Word
The table below shows the fieldbus Status Word for the ABB Drives control profile.
The embedded fieldbus interface converts the drive Status Word into this form
for the fieldbus. The upper case boldface text refers to the states shown in
.
STATE/Description
Value
Name
Bit
READY TO SWITCH ON.
1
RDY_ON
0
NOT READY TO SWITCH ON.
0
READY TO OPERATE.
1
RDY_RUN
1
OFF1 ACTIVE.
0
OPERATION ENABLED.
1
RDY_REF
2
OPERATION INHIBITED.
0
FAULT.
1
TRIPPED
3
No fault.
0
OFF2 inactive.
1
OFF_2_STA
4
OFF2 ACTIVE.
0
OFF3 inactive.
1
OFF_3_STA
5
OFF3 ACTIVE.
0
SWITCH-ON INHIBITED.
1
SWC_ON_ INHIB
6
-
0
Warning/Alarm.
1
ALARM
7
No warning/alarm.
0
Fieldbus control through the embedded fieldbus interface (EFB) 615
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...