Parameters 117
Main status word of the drive.
The bit assignments are described on page
. The
related control word and state diagram are presented on
pages
respectively.
This parameter is read-only.
-
0000h...FFFFh
Main status word.
1 = 1
Drive status word 1.
This parameter is read-only.
-
0000h…FFFFh
Drive status word 1.
1 = 1
No.
Name/Value
Description
Def/
FbEq16
Bit
Name
Description
0
Enabled
) and start
enable (
) signals are present. Note: This bit
is not affected by the presence of a fault.
1
Inhibited
1 = Start inhibited. See parameters
for the
source of the inhibiting signal.
2
DC charged
1 = DC circuit has been charged
3
Ready to start
1 = Drive is ready to receive a start command
4
Following reference 1 = Drive is ready to follow given reference
5
Started
1 = Drive has been started
6
Modulating
1 = Drive is modulating (output stage is being
controlled)
7
Limiting
1 = Any operating limit (speed, torque, etc.) is
active
8
Local control
1 = Drive is in local control
9
Network ctrl
(see page
)
10
Ext1 active
1 = Control location EXT1 active
11
Ext2 active
1 = Control location EXT2 active
12
Reserved
13
Start request
1 = Start requested
14...15 Reserved
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...