Parameters 267
2 × Pt1000 analog I/O As selection
, but with two sensors
connected in series. Using multiple sensors improves
measurement accuracy significantly.
14
3 × Pt1000 analog I/O As selection
, but with three sensors
connected in series. Using multiple sensors improves
measurement accuracy significantly.
15
Defines the fault limit for temperature monitoring function
2. When measured temperature 2 exceeds the limit, the
drive trips on fault
.
The unit is selected by parameter
Note: With a PTC sensor, the unit is ohms.
130 °C or
266 °F
-60…5000 °C or
-76…9032 °F
Fault limit for temperature monitoring function 2.
1 = 1 unit
Defines the warning limit for temperature monitoring
function 2. When measured temperature 2 exceeds the
limit, a warning (
) is
generated.
The unit is selected by parameter
Note: With a PTC sensor, the unit is ohms.
110 °C or
230 °F
-60…5000 °C or
-76…9032 °F
Warning limit for temperature monitoring function 2.
1 = 1 unit
Selects the input for parameter
, selections
,
,
,
Not selected
None.
0
AI1 actual value
Analog input AI1 on the control unit.
1
AI2 actual value
Analog input AI2 on the control unit.
2
Source selection (see
on page
).
-
FEX-01/FPTC-01
configuration word
Activates FEX-01/FPTC-01 temperature monitoring
modules installed on the control unit of the drive. Using this
word, it is also possible to suppress the warnings (but not
faults) from each module.
0000 0000b
0000 0000b … 0011
1111b
FEX-01/FPTC-01 module configuration word.
1 = 1
No.
Name/Value
Description
Def/
FbEq16
Bit
Name
Description
0
Module in slot 1
1 = Yes: Module installed in slot 1.
1
Disable slot 1 warning
1 = Yes: Warnings from the module in slot 1 suppressed.
2
Module in slot 1
1 = Yes: Module installed in slot 2.
3
Disable slot 1 warning
1 = Yes: Warnings from the module in slot 2 suppressed.
4
Module in slot 1
1 = Yes: Module installed in slot 3.
5
Disable slot 1 warning
1 = Yes: Warnings from the module in slot 3 suppressed.
6…15
Reserved
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...