388 Additional parameter data
35.53
Break point
1.00…500.00
Hz
100 = 1 Hz
35.54
Motor nominal temperature
rise
0…300
°C
1 = 1 °C
35.55
Motor thermal time constant
100…10000
s
1 = 1 s
35.60
Cable temperature
00...200.0
%
10 = 1%
35.61
Cable nominal current
0.00...10000.0
A
100 = 1 A
35.62
Cable thermal rise time
0...50000
s
1 = 1 s
35.100
DOL starter control source
-
-
1 = 1
35.101
DOL starter on delay
0...42949673
s
1 = 1 s
35.102
DOL starter off delay
0...715828
min
1 = 1 min
35.103
DOL starter feedback source
-
-
1 = 1
35.104
DOL starter feedback delay
0...42949673
s
1 = 1 s
35.105
DOL starter status word
0000b...1111b
-
1 = 1
35.106
DOL starter event type
0...2
-
1 = 1
36 Load analyzer
36.01
PVL signal source
-
-
1 = 1
36.02
PVL filter time
0.00…120.00
s
100 = 1 s
36.06
AL2 signal source
-
-
1 = 1
36.07
AL2 signal scaling
0.00…32767.00
-
100 = 1
36.09
Reset loggers
0…3
-
1 = 1
36.10
PVL peak value
-32768.00…32767.00
-
100 = 1
36.11
PVL peak date
-
-
1 = 1
36.12
PVL peak time
-
-
1 = 1
36.13
PVL current at peak
-32768.00…32767.00
A
100 = 1 A
36.14
PVL DC voltage at peak
0.00…2000.00
V
100 = 1 V
36.15
PVL speed at peak
-32768.00…32767.00
rpm
100 = 1 rpm
36.16
PVL reset date
-
-
1 = 1
36.17
PVL reset time
-
-
1 = 1
36.20
AL1 0 to 10%
0.00…100.00
%
100 = 1%
36.21
AL1 10 to 20%
0.00…100.00
%
100 = 1%
36.22
AL1 20 to 30%
0.00…100.00
%
100 = 1%
36.23
AL1 30 to 40%
0.00…100.00
%
100 = 1%
36.24
AL1 40 to 50%
0.00…100.00
%
100 = 1%
36.25
AL1 50 to 60%
0.00…100.00
%
100 = 1%
36.26
AL1 60 to 70%
0.00…100.00
%
100 = 1%
36.27
AL1 70 to 80%
0.00…100.00
%
100 = 1%
36.28
AL1 80 to 90%
0.00…100.00
%
100 = 1%
36.29
AL1 over 90%
0.00…100.00
%
100 = 1%
No.
Name
Type
Range
Unit
FbEq32
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...