Fault tracing 427
64A1
Internal file load
File read error.
Note:
This fault cannot be
reset.
Contact your local ABB
representative.
64A2
Internal record load
Internal record load error.
Contact your local ABB
representative.
64A3
Application loading
Application file incompatible
or corrupted.
Note:
This fault cannot be
reset.
Contact your local ABB
representative.
64A5
Licensing fault
Running the control program
is prevented either because
a restrictive license exists, or
because a required license is
missing.
Record the auxiliary codes of all
active licensing faults and contact
your product vendor for further
instructions.
64B1
Internal SSW fault
Internal fault.
Reboot the control unit (using
parameter
) or by cycling power. If the
problem persists, contact your local
ABB representative.
64B2
User set fault
Loading of user parameter
set failed because
requested set does not exist
set is not compatible with
control program
drive was switched off during
loading.
Ensure that a valid user parameter
set exists. Reload.
64E1
Kernel overload
Operating system error.
Note:
This fault cannot be
reset.
Contact your local ABB
representative.
6581
Parameter system
Parameter load or save
failed.
Try forcing a save using parameter
Retry.
65A1
FBA A parameter conflict
The drive does not have a
functionality requested by
PLC, or requested
functionality has not been
activated.
Check PLC programming.
Check settings of parameter
groups
and
6681
EFB comm loss
Programmable fault
Communication break in
embedded fieldbus (EFB)
communication.
Check the status of the fieldbus
master (online/offline/error etc.).
Check cable connections to the
XD2D connector on the control unit.
6682
EFB config file
Embedded fieldbus (EFB)
configuration file could not be
read.
Contact your local ABB
representative.
6683
EFB invalid
parameterization
Embedded fieldbus (EFB)
parameter settings
inconsistent or not compatible
with selected protocol.
Check the settings in parameter
group
.
6684
EFB load fault
Embedded fieldbus (EFB)
protocol firmware could not be
loaded.
Contact your local ABB
representative.
Code
(hex)
Fault
Cause
What to do
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...