Fieldbus control through a fieldbus adapter 473
The start sequence for the parameter example above is given below.
Control word:
• 47Eh (1150 decimal) –> READY TO SWITCH ON
• 47Fh (1151 decimal) –> OPERATING (Speed mode)
Parameter setting example: Using PCP/ESP application through
FPBA
This example shows how to configure a PCP/ESP application for Profibus
communication using ABB Drives profile with PPO Type 8 telegram type. The
start/stop commands are according to the Main control word (
). Reference is according to application reference (
Example:
Assume that pump maximum speed is 80 Prpm and required speed is 60
Prpm. For ABB Drive profile fieldbus speed reference value 20000 corresponds to
maximum motor speed. For gear reduction ratio value 10 (
maximum pump speed 80 Prpm corresponds to fieldbus reference value 2000.
Fieldbus reference for 60 Prpm can be calculated as: 60 * 2000/ 80 = 1500.
Speed ref 1 in PZD 2 OUT should be equal to 1500.
If actual value 1 in PZD 2 IN equals 50, then pump speed is 50 Prpm.
The table below gives the recommended drive parameter settings.
The table below gives the recommended drive parameter settings.
Direction
PZD1
PZD2
PZD3
PZD4
Out
Main control word
Speed ref1
In
Drive status word
Rod speed
Rod torque
Direction
PZD5
PZD6
PZD7
PZD8
Out
In
Output frequency
Pump status word
Drive parameter
Setting for
ACS880 drive
Description
Fieldbus A
Selects the source of start command.
Option slot 3
Enables communication between the drive and the
fieldbus adapter module.
Fieldbus adapter module must be attached to slot 3.
51.02 Node address
3
2)
Defines the PROFIBUS node address of the fieldbus
adapter module.
51.03 Baud rate
12000
1)
Displays the current baud rate on the PROFIBUS
network in kbit/s.
51.05 Profile
ABB Drives
2)
Selects the Control word according to the ABB Drives
profile.
51.27 FBA A par refresh
Refresh
Validates the configuration parameter settings.
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...