Parameters 105
Parameter listing
No.
Name/Value
Description
Def/
FbEq16
01
Basic signals for monitoring the drive.
All parameters in this group are read-only unless otherwise
noted.
Measured or estimated motor speed depending on which
type of feedback is used (see parameter
). A filter time constant for this signa46l
can be defined by parameter
46.11 Filter time motor
speed
.
-
-30000.00
…30000.00 rpm
Measured or estimated motor speed.
See par.
Estimated motor speed in rpm. A filter time constant for
this signal can be defined by parameter
46.11 Filter time
motor speed
.
-
-30000.00
…30000.00 rpm
Estimated motor speed.
See par.
Shows the value of
in percent of
the synchronous speed of the motor.
10 = 1%
-1000.00 …
1000.00%
Measured or estimated motor speed.
See par.
Speed of encoder 1 in rpm. A filter time constant for this
signal can be defined by parameter
46.11 Filter time motor
speed
.
-
-30000.00
…30000.00 rpm
Encoder 1 speed.
See par.
Speed of encoder 2 in rpm. A filter time constant for this
signal can be defined by parameter
46.11 Filter time motor
speed
.
-
-30000.00
…30000.00 rpm
Encoder 2 speed.
See par.
Estimated drive output frequency in Hz. A filter time
constant for this signal can be defined by parameter
46.12
Filter time output frequency
.
-
-500.00
…500.00 Hz
Estimated output frequency.
See par.
Measured (absolute) motor current in A.
-
0.00…30000.00 A
Motor current.
See par.
46.05
Motor torque in percent of the nominal motor torque. See
also parameter
.
A filter time constant for this signal can be defined by
parameter
46.13 Filter time motor torque
.
-
-1600.0…1600.0%
Motor torque.
See par.
46.03
Measured DC link voltage.
-
0.00…2000.00 V
DC link voltage.
10 = 1 V
Calculated motor voltage in V AC.
-
0...2000 V
Motor voltage.
1 = 1 V
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...