Parameters 119
Start inhibit status word. This word specifies the source of
the inhibiting signal that is preventing the drive from
starting.
The conditions marked with an asterisk (*) only require that
the start command is cycled. In all other instances, the
inhibiting condition must be removed first.
See also parameter
, bit 1.
This parameter is read-only.
-
0000h…FFFFh
Start inhibit status word.
1 = 1
No.
Name/Value
Description
Def/
FbEq16
Bit
Name
Description
0
Not ready run
1 = DC voltage is missing or drive has not been
parametrized correctly. Check the parameters in groups
95 and 99.
1
Ctrl location
changed
* 1 = Control location has changed
2
SSW inhibit
1 = Control program is keeping itself in inhibited state
3
Fault reset
* 1 = A fault has been reset
4
Lost start enable
1 = Start enable signal missing
5
Lost run enable
1 = Run enable signal missing
6
FSO inhibit
1 = Operation prevented by FSO-xx safety functions
module
7
STO
1 = Safe torque off active
8
Current calibration
ended
* 1 = Current calibration routine has finished
9
ID run ended
* 1 = Motor identification run has finished
10
Auto phase ended * 1 = Autophasing routine has finished
11
Em Off1
1 = Emergency stop signal (mode off1)
12
Em Off2
1 = Emergency stop signal (mode off2)
13
Em Off3
1 = Emergency stop signal (mode off3)
14
Auto reset inhibit
1 = The autoreset function is inhibiting operation
15
Jogging active
1 = The jogging enable signal is inhibiting operation
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...