Additional parameter data 369
11.55
Freq out 1 source
-
-
1 = 1
11.58
Freq out 1 src min
-32768.000…32767.000
-
1000 = 1
11.59
Freq out 1 src max
-32768.000…32767.000
-
1000 = 1
11.60
Freq out 1 at src min
0…16000
Hz
1 = 1 Hz
11.61
Freq out 1 at src max
0…16000
Hz
1 = 1 Hz
11.81
DIO filter time
0.3 … 100.0
ms
10 = 1 ms
12 Standard AI
12.01
AI tune
enum
0...4
-
12.03
AI supervision function
0...4
-
1 = 1
12.04
AI supervision selection
0000h…FFFFh
-
1 = 1
12.11
AI1 actual value
-22.000…22.000
V or mA
1000 = 1 unit
12.12
AI1 scaled value
-32768.000…32767.000
-
1000 = 1
12.15
AI1 unit selection
-
-
1 = 1
12.16
AI1 filter time
0.000…30.000
s
1000 = 1 s
12.17
AI1 min
-22.000…22.000
mA or V
1000 = 1 mA
or V
12.18
AI1 max
-22.000…22.000
mA or V
1000 = 1 mA
or V
12.19
AI1 scaled at AI1 min
-32768.000…32767.000
-
1000 = 1
12.20
AI1 scaled at AI1 max
-32768.000…32767.000
-
1000 = 1
12.21
AI2 actual value
-22.000…22.000
mA or V
1000 = 1 mA
or V
12.22
AI2 scaled value
-32768.000…32767.000
-
1000 = 1
12.25
AI2 unit selection
-
-
1 = 1
12.26
AI2 filter time
0.000…30.000
s
1000 = 1 s
12.27
AI2 min
-22.000…22.000
mA or V
1000 = 1 mA
or V
12.28
AI2 max
-22.000…22.000
mA or V
1000 = 1 mA
or V
12.29
AI2 scaled at AI2 min
-32768.000…32767.000
-
1000 = 1
12.30
AI2 scaled at AI2 max
-32768.000…32767.000
-
1000 = 1
13 Standard AO
13.11
AO1 actual value
0.000…22.000
mA
1000 = 1 mA
13.12
AO1 source
-
-
1 = 1
13.16
AO1 filter time
0.000…30.000
s
1000 = 1 s
13.17
AO1 source min
-32768.0…32767.0
-
10 = 1
13.18
AO1 source max
-32768.0…32767.0
-
10 = 1
13.19
AO1 out at AO1 src min
0.000…22.000
mA
1000 = 1 mA
13.20
AO1 out at AO1 src max
0.000…22.000
mA
1000 = 1 mA
13.21
AO2 actual value
0.000…22.000
mA
1000 = 1 mA
No.
Name
Type
Range
Unit
FbEq32
Summary of Contents for ACS880 PCP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...