12 Quick start-up guide
Optical link for Decanter
To realize the internal drives communication, an optical link is required between the Bowl
drive and the Scroll drive. Connect channel 2 of both drives together using a pair of fibre
optic cable (2 m to 10 m).
Figure 1. Optical link connection (T = Transmitter, R = Receiver)
Parameter settings
Configure Bowl drive and Scroll drive using the following parameters:
Bowl drive parameters:
•
60.01 M/F communication port (fiber optic channel selection) = Slot 1B. See
ACS880 primary control program firmware manual (3AUA0000085967[English]).
•
60.02 M/F node address = 1. See
ACS880 primary control program firmware
manual (3AUA0000085967[English]).
•
60.12 M/F act1 type = Speed. See
ACS880 primary control program firmware
manual (3AUA0000085967[English]).
•
Centrifuge/ Decanter function selection
•
FDCO - 01
DDCS link
FDCO - 01
DDCS link
ACS880
ACS880
Bowl drive
Scroll drive
Bowl actual speed
Bowl speed scaling factor
Control word
Torque limit status
CH2
CH2
V2T V2R
V1T V1R
V1T V1R
V2T V2R
Scroll status word