Signals and parameters 39
78.17
Load
compensation gain
Defines load compensation function proportional gain.
0.0
0.0...100.0
Load compensation gain.
-
78.18
Load
compensation int
time
Defines load compensation function integration time.
0 = Load compensation is disabled.
0.0 s
0.0...3000.0 s
Load compensation integration time in seconds.
-
78.19
Torque to delta
speed
Defines direct torque compensation proportional gain.
0 = Direct torque compensations is disabled.
1.0 rpm
0.0...1500.0 rpm
Torque to differential speed.
-
78.20
Delta speed min
limit
Defines minimum differential speed (delta speed).
0.0 rpm
0.0...1500.0 rpm
Minimum differential speed.
-
78.21
Delta speed max
limit
Defines maximum differential speed (delta speed).
1500.0 rpm
0.0...1500.0 rpm
Maximum differential speed.
-
78.22 Clean-up select
Selects the source to activate Clean-up function. The
function delays the Stop command for 200 ms. The
Scroll drive remains running if the DC undervoltage
controller of the Bowl drive is active even if the Start
command is not active.
0 = Clean-up function is not active
1 = Clean-up function is active.
Not selected
Not selected
Not selected.
0
Selected
Selected
1
DI1
Activate Clean-up function through DI1.
2
DI2
Activate Clean-up function through DI2.
3
DI3
Activate Clean-up function through DI3.
4
DI4
Activate Clean-up function through DI4.
5
DI5
Activate Clean-up function through DI5.
6
DI6
Activate Clean-up function through DI6.
7
Comm CW
Fieldbus communication control word.
8
-
78.23 Acceleration time
Defines acceleration time for decanter.
20 s
0...3000 s
Acceleration time in seconds.
-
78.24 Deceleration time
Defines deceleration time for decanter.
20 s
0...3000 s
Deceleration time in seconds.
-
Parameters
No
Name/Value
Description
Def
/
FbEq16