Standard function blocks
293
TOF
(10058)
Illustration
Execution time
1.10 µs
Operation
The output (Q) is set to 1, when the input (IN) is set to 1. The output is reset to zero
when the input has been 0 for a time defined by the pulse time input (PT).
Elapsed time count (TE) starts when the input is set to 0 and stops when the input is set
to 1.
Example:
Inputs
Input (IN): Boolean
Pulse time input (PT): DINT (1 = 1 µs)
Outputs
Output (Q): Boolean
Elapsed time output (ET): DINT (1 = 1 µs)
TON
(10059)
Illustration
Execution time
1.22 µs
TOF
86
TLA1 1 msec
(1)
IN
PT
ET
ET(86)
Q
Q(86)
IN
Q
PT
ET
ET
ET
PT
TON
87
TLA1 1 msec
(1)
IN
PT
ET
ET(87)
Q
Q(87)