Parameters and firmware blocks
125
Group
Configuration of signal supervision.
33
33 SUPERVISION
Firmware block:
SUPERVISION
(17)
Block outputs located in other
parameter groups
(page
)
33.01
SUPERV1 FUNC
(see above)
Selects the mode of supervision 1.
(0)
DISABLED
Supervision 1 not in use.
(1)
LOW
When the signal selected by parameter
falls
, bit 0 of
is activated.
(2)
HIGH
When the signal selected by parameter
exceeds the value of parameter
, bit 0 of
is activated.
(3)
ABS LOW
When the absolute value of the signal selected by parameter
falls below the value of parameter
, bit 0 of
is activated.
(4)
ABS HIGH
When the absolute value of the signal selected by parameter
exceeds the value of parameter
, bit 0 of
is activated.
33.02
SUPERV1 ACT
(see above)
Selects the signal to be monitored by supervision 1. See parameter
Value pointer: Group and index
33.03
SUPERV1 LIM HI
(see above)
Sets the upper limit for supervision 1. See parameter
SUPERVISION
45
TLF11 10 msec
(6)
33.01 SUPERV1 FUNC
[ Disabled ]
< 33.02 SUPERV1 ACT
[ SPEED ACT ]
(7 / 1.01)
33.03 SUPERV1 LIM HI
[ 0.00 ]
33.04 SUPERV1 LIM LO
[ 0.00 ]
33.05 SUPERV2 FUNC
[ Disabled ]
< 33.06 SUPERV2 ACT
[ CURRENT ]
(1 / 1.04)
33.07 SUPERV2 LIM HI
[ 0.00 ]
33.08 SUPERV2 LIM LO
[ 0.00 ]
33.09 SUPERV3 FUNC
[ Disabled ]
< 33.10 SUPERV3 ACT
[ TORQUE ]
(1 / 1.06)
33.11 SUPERV3 LIM HI
[ 0.00 ]
33.12 SUPERV3 LIM LO
[ 0.00 ]
6.14 SUPERV STATUS
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Page 2: ......
Page 4: ......
Page 12: ...Table of contents 12...
Page 49: ...Drive control and features 49...
Page 282: ...Standard function blocks 282...
Page 306: ...Application program template 306...
Page 312: ...Control chain block diagrams 312...
Page 331: ...331...
Page 332: ...332...
Page 333: ......