Parameters and firmware blocks
126
-32768…32768
Upper limit for supervision 1.
33.04
SUPERV1 LIM LO
FW block:
(see above)
Sets the lower limit for supervision 1. See parameter
-32768…32768
Lower limit for supervision 1.
33.05
SUPERV2 FUNC
FW block:
(see above)
Selects the mode of supervision 2.
(0)
DISABLED
Supervision 2 not in use.
(1)
LOW
When the signal selected by parameter
falls
below the value of parameter
, bit 1 of
is activated.
(2)
HIGH
When the signal selected by parameter
exceeds the value of parameter
, bit 1 of
is activated.
(3)
ABS LOW
When the absolute value of the signal selected by parameter
falls below the value of parameter
, bit 1 of
is activated.
(4)
ABS HIGH
When the absolute value of the signal selected by parameter
exceeds the value of parameter
, bit 1 of
is activated.
33.06
SUPERV2 ACT
FW block:
(see above)
Selects the signal to be monitored by supervision 2. See parameter
Value pointer: Group and index
33.07
SUPERV2 LIM HI
FW block:
(see above)
Sets the upper limit for supervision 2. See parameter
-32768…32768
Upper limit for supervision 2.
33.08
SUPERV2 LIM LO
FW block:
(see above)
Sets the lower limit for supervision 2. See parameter
-32768…32768
Lower limit for supervision 2.
33.09
SUPERV3 FUNC
FW block:
(see above)
Selects the mode of supervision 3.
(0)
DISABLED
Supervision 3 not in use.
(1)
LOW
When the signal selected by parameter
falls
below the value of parameter
, bit 2 of
is activated.
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Page 2: ......
Page 4: ......
Page 12: ...Table of contents 12...
Page 49: ...Drive control and features 49...
Page 282: ...Standard function blocks 282...
Page 306: ...Application program template 306...
Page 312: ...Control chain block diagrams 312...
Page 331: ...331...
Page 332: ...332...
Page 333: ......