Standard function blocks
258
Operation
The output (Q1) is 0 if the set input (S) is 1 and the reset input (R) value is 0. The output
will retain the previous output state if the set input (S) and the reset input (R) are 0. The
output is 0 if the set input is 0 and the reset input is 1.
Truth table:
Inputs
Set input (S): Boolean
Reset input (R): Boolean
Outputs
Output (Q1): Boolean
RTRIG
(10031)
Illustration
Execution time
0.38 µs
Operation
The output (Q) is set to 1 when the clock input (CLK) changes from 0 to 1. The output is
set back to 0 with the next execution of the block. Otherwise the output is 0.
Note:
The output is 0 after cold restart and after the first execution of the RTRIG block.
Otherwise the output is 1, when the clock input is 1.
Inputs
Clock input (CLK): Boolean
Outputs
Output (Q): Boolean
S
R
Q1
previous
Q1
0
0
0
0
0
0
1
1
0
1
0
0
0
1
1
0
1
0
0
1
1
0
1
1
1
1
0
0
1
1
1
0
Q
previous
is the previous cycle output value.
RTRIG
47
TLA1 1 msec
(1)
>CLK
Q
Q(47)
CLK
previous
CLK
Q
0
0
0
0
1
1
1
0
0
1
1
0
CLK
previous
is the previous cycle output value.
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Page 2: ......
Page 4: ......
Page 12: ...Table of contents 12...
Page 49: ...Drive control and features 49...
Page 282: ...Standard function blocks 282...
Page 306: ...Application program template 306...
Page 312: ...Control chain block diagrams 312...
Page 331: ...331...
Page 332: ...332...
Page 333: ......