267
Inputs
Minimum current signal (AO Min): REAL (0…20 mA)
Maximum current signal (AO Max): REAL (0…20 mA)
Minimum input signal (AO Min Scale): REAL
Maximum input signal (AO Max Scale): REAL
Input signal (AO scaled): REAL
Outputs
Analogue output current value (AO): REAL
Error output (Error): DINT (0 = No error; 1 = Application program memory full)
FIO_11_AO_slot2
(10091)
Illustration
Execution time
4.9 µs
AO Min > AO Max
AO [mA]
0
20
AO scaled
32768
-32768
0
AO Max Scal
e
AO Mi
n
Sca
le
AO Max
AO Min
FIO_11_AO_slot2
54
TLA1 1 msec
(1)
AO Min
AO Max
AO Min Scale
AO Max Scale
AO scaled
AO
AO(54)
Error
Error(54)