Parameters and firmware blocks
77
10.11
EM STOP OFF1
(see above)
Selects the source for the emergency stop OFF1. 0 = OFF1 active: The drive is stopped with the
active deceleration time.
Emergency stop can also be activated through fieldbus (
See section
on page
Note:
This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.12
START INHIBIT
(see above)
Enables the start inhibit function. The start inhibit function prevents drive restart (i.e. protects against
unexpected start) if
• drive trips on a fault and fault is reset.
• run enable signal activates while the start command is active. See parameter
.
• control changes from local to remote.
• external control switches from EXT1 to EXT2 or from EXT2 to EXT1.
An active start inhibit can be reset with a stop command.
Note that in certain applications it is necessary to allow the drive to restart.
(0)
DISABLED
Start inhibit function disabled.
(1)
ENABLED
Start inhibit function enabled.
10.13
FB CW USED
(see above)
Selects the source for the control word when fieldbus (FBA) is selected as the external start and stop
control location (see parameters
and
). By
default, the source is parameter
.
Note:
This parameter cannot be changed while the drive is running.
Value pointer: Group and index
10.14
JOG2 START
(see above)
If enabled by parameter
, selects the source for the activation of jogging function
2. 1 = Active. (Jogging function 2 can also be activated through fieldbus regardless of parameter
Note:
This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.15
JOG ENABLE
(see above)
Selects the source for enabling parameters
.
Note:
Jogging can be enabled using this parameter only when no start command from an external
control location is active. On the other hand, if jogging is already enabled, the drive cannot be started
from an external control location apart from jog commands through fieldbus.
Bit pointer: Group, index and bit
10.16
D2D CW USED
(see above)
Selects the source for the control word for drive-to-drive communication. By default, the source is
parameter
Summary of Contents for ACSM1 Series
Page 1: ...ACSM1 Firmware Manual ACSM1 Speed and Torque Control Program...
Page 2: ......
Page 4: ......
Page 12: ...Table of contents 12...
Page 49: ...Drive control and features 49...
Page 282: ...Standard function blocks 282...
Page 306: ...Application program template 306...
Page 312: ...Control chain block diagrams 312...
Page 331: ...331...
Page 332: ...332...
Page 333: ......