3. Assembly the new internal fan and check that the blowing direction is to upwards. Remember
to reinstall the transparent plastic cover and the wires.
2.2.5 Old Frame R1, Main cooling fan
Types:
•
ACX580-01-07A2-4
•
ACX580-01-09A4-4
•
ACX580-01-12A6-4
The main cooling fan is located at the bottom of the drive. Replace the fan as follows:
a. Release two locking clamps, use a flathead screwdriver to assist
b. Remove the fan
c. Clean the cooling air duct and the heat sink with compressed air. See separate instructions in
section 2.1.1
d. Check that the fans blowing direction is inside the unit and install the new fan in reverse order
to above. Ensure the fan operation when the drive is powered up