2.2.19 Old Frame R5, Main cooling fan
Types:
•
ACX580-01-061A-4
•
ACX580-01-072A-4
•
ACX580-01-087A-4
The main cooling fan is located at the top of the drive. Replace the fan as follows:
e. Release the locking clamp, use a flathead screwdriver to assist
f. Lift the fan off the drive (when the drive is in upward position). Release the fan wire from the
drive and remove the fan
g. Clean the cooling air duct and the heat sink with compressed air. See separate instructions in
section 2.1.1
h. Check that the fans blowing
direction is outwards from
the unit. Attach the fan wire
to the drive and install the
new fan.
Ensure the fan operation
when the drive is powered up
2.2.20 Old Frame R5, Internal
cooling fan
Types:
•
ACX580-01-061A-4
•
ACX580-01-072A-4
•
ACX580-01-087A-4
Remove front cover
a. Remove control panel
b. Open six mounting screw with a screwdriver
c. Push the front cover slightly upwards and lift it off
Replace internal fan
a. Remove internal fan and cable from skeleton kit clamps
b. Assemble internal fan + grill with plastic rivets
c. Place internal fan to skeleton kit and attach fan cable
Install components in reverse order