Configuration • Software • OPC UA server
Power Panel FT50 User's manual V1.19
95
Path to the object directory:
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Configuration
7.3.4.2.2.1 Audio
Path to the object directory:
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Configuration/4:Audio
ns BrowseName of the parameter
Description
Service page R W
Enables/Disables the buzzer.
+ +
Selects the trigger for the buzzer.
+ +
Frequency of the buzzer.
+ +
4
Duration of the buzzer.
+ +
EnableBuzzer
Function identical to:
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/2:ParameterSet/4:EnableBuzzer
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Configuration/4:Audio/4:EnableBuzzer
Node attributes
NodeClass
Variable
DataType
Boolean
AccessLevel
CurrentRead, CurrentWrite
UserAccessLevel
CurrentRead, CurrentWrite
BuzzerSource
Function identical to:
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/2:ParameterSet/4:BuzzerSource
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Configuration/4:Audio/4:BuzzerSource
Node attributes
NodeClass
Variable
DataType
BrBuzzerSource (Enumeration)
AccessLevel
CurrentRead, CurrentWrite
UserAccessLevel
CurrentRead, CurrentWrite
Data type
BrBuzzerSource
(enumeration)
Value
String
0
App
1
Touch
BuzzerFrequency
Function identical to:
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/2:ParameterSet/4:BuzzerFrequency
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelFT50/3:Configuration/4:Audio/4:BuzzerFrequency
Node attributes
NodeClass
Variable
DataType
UInt16
AccessLevel
CurrentRead, CurrentWrite
UserAccessLevel
CurrentRead, CurrentWrite