Installation
Power Panel FT50 User's manual V1.19
33
5.3.3 FT50 PoE cable - M22/RJ45, USB
6CAPFT.0030-02 / 6CAPFT.0050-02
Notice!
In order to ensure sufficient contact between the pins on the connection, the cable must be secured
to the panel with a torque of at least 1.5 Nm.
It is important to note that this torque ensures the functionality of the USB connection and does not
ensure IP67 protection (for more information, see
Installing different cable types
1. Connect the Ethernet connector to the panel.
2. Tighten the cable gland (Torque: 3.0 Nm).
"FT50 PoE cable - M22/RJ45" on page 32
.)
5.3.4 FT50 PoE cable - M22/M22
6CAPFT.0050-03
1. First connect one end of the cable to the injector.
Information:
For the procedure for installing an injector, see section
"Mounting the injector" on page 31
.
2. Connect the other end of the cable to the panel (see steps 1 to 2 in section
3. Tighten the cable gland (Torque: 3.0 Nm).