1 Preparation
2
IM/C1300 Rev. J
1 Preparation
1.1 Preparing the Recorder for First Use
Prepare the recorder for first use as follows:
1. Install the recorder – see Section 4, page 60.
2. Connect the recorder – see Section 5, page 64.
3. Switch on the power supply to the recorder.
4. Fit the pen capsule(s) – see Fig. 1.1.
5. Fit a chart – see Fig. 1.2 on page 3.
Warning.
Ensure all connections are made correctly,
especially to the earth (ground) stud – see Section
5.4, page 71.
Note.
On power-up, the pen arm(s) is (are) moved to
an off-chart position for automatic referencing. Pen
chatter may occur on the pen(s) nearest the reference
position. This is a normal function of the recorder.
Note.
Ensure the correct colored capsule is fitted to
the appropriate pen arm. Each pen arm is
identified by a colored band – see Fig. 1.1.
If the violet, true-time line event option is fitted,
the pen records on the same time line as the red
pen, but on the outer edge of the chart.
Fig. 1.1 Fitting the Pen Capsule(s)
Gently pull
the pen arm
off its bracket
3
Note.
Do not bend the pen arm during removal
and re-fitting as pen clashing may result.
Raise pens
1
Input 1
-999.99
deg C
5
Remove cap
Fit the correct colored pen
capsule ensuring that the arm
locates in the pen
capsule slot
4
Red Pen
(Channel 1)
Green Pen
(Channel 2)
Blue Pen
(Channel 3)
Black Pen
(Channel 4)
2
Identify pens
Note.
The number of pens fitted (and
the colors of the pen capsules
supplied) depends on the recorder
model.
Slide pen arm and capsule
assembly onto the appropriate
bracket until it clips into place
6
ensuring that the arm is
positioned above its lifter bar
7
Repeat steps to for
remaining pens as required
3
6