Page 21
© Copyright 2021 ABB. All rights reserved.
Table 2
-
J: QS820A Ringer Specifications
Input Voltage
-
40 to
-
57 V
dc
See Output VA Thermal Limiting.
Nominal Input Voltage
-
48 V
dc
Input Current
5 A max.
Output
Voltage
ac Component
65 to 100 V
ac
Factory Default: 100Vac
ac tolerance
± 5 V
ac
Regulation
±5% ac component only
dc Offset
Type of ringing Battery Backed Ground Backed
Ground Backed no
-
dc
•
-
40 to +57 Vdc Battery Backed
•
·+40 to +57 V
dc
Ground Backed
•
0 V
dc
Offset Disabled
•
dc Offset tracks dc Input Voltage
•
Factory Default: Enabled
•
Battery or Ground Backed is selected by Ringer Chassis
jumper J12 or by external connection of Ring Rtn to Bat-
tery or to Ground. Factory Default: Battery Backed by
Jumper
See figures in the Ringer section.
dc Offset Tracking
Error
± 3 V
dc
Harmonic Distortion
5% THD
Crest Factor
1.21 to 1.51
Output Frequency
15 to 50 Hz
Factory Default: 20 Hz
Frequency tolerance
± 1 Hz
Output VA
100 VA
Thermal Limiting
Output VA may be reduced by reducing Vac when operating
simultaneously above 50°C and less than
-
50V
dc
input.
Vac is reduced only sufficiently to prevent damage to the
ringer.
Load Power Factor
Operating: 0.5 Leading to 0.9 Lagging
No Damage: 0 Leading to 0.7 Lagging
Operating Temperature
-
40 to +75 °C
See Output VA Thermal Limiting.
Heat Dissipation
50 W (170 BTU / hr)
Under Voltage Shutdown
50% of Output V
ac
Set Point
While shutdown due to external fault, restart will be
performed at approximately 2 minute intervals.
Table 2
-
K: QS840A and QS841A Control Unit Specifications
Operating Input Voltage Range
38 to 60 V
dc
Input Power
6.0 watts maximum
Plant Parameter Setting
Through front panel LCD display and menu keys or with IBM
compatible PC with RS
-
232 port. 841 also has 10/100 Baset
-
T
network ability
Alarm Contact Ratings
60 V
dc
, 0.5A, Form
-
C
Operating Temperature
-
40 to +75 °C
Summary of Contents for CPS6000
Page 6: ...Page 6 Copyright 2021 ABB All rights reserved This page intentionally left blank Jl ll ll ...
Page 36: ...Page 36 Copyright 2021 ABB All rights reserved This page intentionally left blank Jl ll ll ...
Page 82: ...Page 82 Copyright 2021 ABB All rights reserved This page intentionally left blank Jl ll ll ...
Page 98: ...Page 98 Copyright 2021 ABB All rights reserved This page intentionally left blank Jl ll ll ...
Page 124: ...Page 124 Copyright 2021 ABB All rights reserved This page intentionally left blank ...
Page 146: ...Page 146 Copyright 2021 ABB All rights reserved This page intentionally left blank ...
Page 152: ...Page 152 Copyright 2021 ABB All rights reserved This page intentionally left blank ...
Page 174: ...Page 174 Copyright 2021 ABB All rights reserved This page intentionally left blank ...
Page 188: ...Page 188 Copyright 2021 ABB All rights reserved This page intentionally left blank ...
Page 192: ...Page 192 Copyright 2021 ABB All rights reserved This page intentionally left blank ...
Page 196: ...Page 196 Copyright 2021 ABB All rights reserved This page intentionally left blank ...
Page 198: ...Page 198 Copyright 2021 ABB All rights reserved This page intentionally left blank ...