Note
Action
xx1800002467
Remove the SMB cover attachment screws and
carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
There are cabling attached to the cover. The
cover cannot be removed completely until the
connectors are removed.
3
xx1800002468
Disconnect the connectors.
•
SMB.P7
•
SMB.J1
•
SMB.J2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
4
Remove the SMB cover completely from the base.
5
Opening the connector interface plate
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
328
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......