Disconnecting the axis-6 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1800002994
Disconnect the connectors.
•
MP6
•
FB6
2
Removing the axis-6 motor
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
2
xx1800002995
Loosen the screws and move the motor slightly
to slacken the timing belt.
3
Continues on next page