Reconnecting the axis-5 motor connectors
Note
Action
xx1800003025
Reconnect the connectors.
•
FB5
•
MP5
Tip
See the number markings on the connectors for
help to find the corresponding connector.
1
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
Insert the cabling and connectors into the wrist.
3
Refitting the process hub
Note
Action
xx1800002946
Reconnect the lamp unit connector J5.UL and
place the connector behind the air hose connect-
ors.
1
xx1800002945
Reconnect the air hoses in a cross pattern.
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same Y-shaped connector.
2
Continues on next page
472
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the extender unit and wrist
Continued
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......