Note
Action
xx1800002491
Snap loose and remove the female head of the
connector from the connector plate.
6
xx1800002492
Remove the swing cover.
7
xx1800002495
Disconnect the connector.
•
MP2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
8
xx1800002493
Loosen the screws and move the motor slightly
to slacken the timing belt.
9
Continues on next page
494
Product manual - CRB 1100
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.7.2 Replacing the axis-2 motor
Continued
Summary of Contents for CRB 1100
Page 1: ...ROBOTICS Product manual CRB 1100 ...
Page 162: ...This page is intentionally left blank ...
Page 184: ...This page is intentionally left blank ...
Page 652: ...This page is intentionally left blank ...
Page 698: ...This page is intentionally left blank ...
Page 712: ...This page is intentionally left blank ...
Page 714: ...This page is intentionally left blank ...
Page 719: ......