Note
Action
xx1800002491
Snap loose and remove the female head of the
connector from the connector plate.
6
xx1800002492
Remove the swing cover.
7
xx1800002495
Disconnect the connector.
•
MP2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
8
xx1800002493
Loosen the screws and move the motor slightly
to slacken the timing belt.
9
Continues on next page
Product manual - CRB 1100
591
3HAC078007-001 Revision: J
© Copyright 2021-2023 ABB. All rights reserved.
5 Repair
5.8.2 Replacing the axis-2 gearbox
Continued